Part Number Hot Search : 
MK5811A 82NJ4K5 D1212 0G101 XX1000 MAX3865D C1455 P6KE20
Product Description
Full Text Search
 

To Download MAP130-1024G Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  bel power solutions map130 series of single and multiple output power supplies provide fully - regulated outputs with high peak current capabilities in a compact 4.5 x 8.5 x 2.0 inch u - channel chassis. other standard features include auto select ac input, emi level b filtering, power fail, thermal shutdown (with warning), remote sense, and metric and sae mounting inserts. this convection - cooled series is designed for use in commercial and industrial environments in temperatures up to 50c. all products are approved to the latest international regulatory standards and display the ce mark. ? rohs compliant ? automatic 115/230 input voltage selection ? all outputs fu lly regulated ? remote sense, overvoltage protection and overtemperature protection ? power fail signal included ? greater than 100,000 hour mtbf ? u - channel chassis: 8.5 x 4.5 x 2.0 inch (215.9 x 114.3 x 50.8 mm) ? optional cover ? metric and sae mounting inserts
2 map130 series tech.support@psbel.com model 6 output voltage adjustment range continuous current peak current 1 line regulation load regulation ripple & noise 2 initial setting accuracy map130 - 1005 g 5v 4.75v to 5.50v 26a 30a 0.2% 1% 1% 5.1v to 5.2v map130 - 1012 g 12/15v 11.4v to 15.75v 12a/10a 3 13.8a/11a 3 0.2% 1% 1% 12.0v to 12.2v map130 - 1024 g 24v/28v 22.5v to 30.0v 6.25a/5.4a 3 6.8a/5.9a 3 0.2% 1% 1% 23.9v to 24.1v model 6 output voltage adjustment range output current peak current 4 line regulation load regulation ripple & noise 5 initial setting accuracy map130 - 4000 g +5v 4.75v to 5.50v 20a 30a 0.2% 1% 1% 5.1v to 5.2v +12v 11.5v to 12.5v 5a 10a 0.5% 2% 1% 11.75v to 12.0v - 5v fixed 1a 1a 0.5% 2% 1% - 4.8v to - 5.2v - 12v fixed 1a 1a 0.5% 2% 1% - 11.6v to - 12.4v map130 - 400g +5v 4.75v to 5.50v 20a 30a 0.2% 1% 1% 5.1v to 5.2v +24v 23.0v to 25.0v 3.5a 5a 0.5% 2% 1% 23.9v to 24.1v - 12v fixed 1a 1a 0.5% 2% 1% - 11.6v to - 12.4v +12v fixed 1a 1a 0.5% 2% 1% - 11.6v to - 12.4v map130 - 4002 g +5v 4.75v to 5.50v 20a 30a 0.2% 1% 1% 5.1v to 5.2v +12v 11.5v to 12.5v 5a 10a 0.5% 2% 1% 11.9v to 12.1v - 12v fixed 1a 1a 0.5% 2% 1% - 11.6v to - 12.4v +12v fixed 1a 1a 0.5% 2% 1% 11.6v to 12.4v map130 - 4003 g +5v 4.75v to 5.50v 20a 30a 1% 1% 1% 5.1v to 5.2v +15v 14.0v to 16.0v 4a 8a 1% 2% 1% 15.0v to 15.1v - 5v fixed 1a 1a 2% 2% 1% - 4.8v to - 5.2v - 15v fixed 1a 1a 2% 2% 1% - 14.7v to - 15.3v map130 - 4010 g +5v 4.75v to 5.50v 20a 30a 0.2% 1% 1% 5.1v to 5.25v +12v 11.5v to 12.8v 5a 10a 0.5% 2% 1% 11.75v to 12.0v - 5v fixed 1a 1a 0.5% 2% 1% - 4.8v to - 5.2v - 12v fixed 3a 3a 0.5% 2% 1% - 11.6v to - 12.4v 1 peak load for 60 seconds or less are acceptable, 10% duty cycle, maximum. 2 typical peak to peak noise expressed as a percentage of output voltage, 20mhz bandwidth. 3 map130 - 1012 output currents are expressed as 12v/15v operation. map130 - 1024 output currents are expressed as 24v/28v operation. 4 peak loads up to 165 watts, (total of all outputs), for 60 seconds or less are acceptable, (10% duty cycle max.). 5 maximum p eak to peak noise expressed as a percentage of output voltage, 20mhz bandwidth. 6 n on - g models use lead solder exemption model numbers highlighted in yellow are not recommended for new designs.
map130 series 3 asia - pacific +86 755 298 85888 europe, middle east +353 61 225 977 north america +1 408 785 5200 ? 2016 bel power solutions & protection bcd.00567 _a c parameter conditions / description min nom max units input voltage - ac auto - ranging low range high range 90 175 115 230 132 264 vac input frequency ac input 47 63 hz brown out protection lowest ac input voltage when regulation is maintained with full rated loads. 90 vac hold - up time nominal ac input voltage (115 vac) 130 w load: 40 ms input current 90 vac, 130 w load 3.3 a rms input protection non - user serviceable internally located ac input line fuse. inrush surge current internally limited by thermistor. vin = 264 vac (one cycle). 25 c. 38 a pk operating frequency switching frequency of main transformer. range: 16 120 khz parameter conditions / description min nom max units efficiency full load @ 115 vac (varies with distribution of loads among outputs.) 71% typical minimum loads map130 - 1012 map130 - 1024 map130 - 1005 and all multiple output models, main channel only 1.25 0.63 3.00 amps ripple and noise full load, 20 mhz bandwidth. see model selection chart output power continuous output power, all multiple output models. peak output power (60s max., 10% duty cycle), all multiple output models. 130 165 watts overshoot / undershoot output voltage overshoot/undershoot at turn - on / turn - off. 1 % regulation varies by output, regulation includes: line changes from 90 - 132 vac or 175 - 264 v , changes in load starting at 20% load and changing to 100% load. see model selection chart transient response recovery time, to within 1% of initial set point due to a 50 - 100% load change, 4% max. deviation. (main output only on multiple output units). 500 s turn - on delay time required for initial output voltage stabilization. 2 sec turn - on rise time time required for output voltage to rise from 10% to 90%. 20 ms parameter conditions / description min nom max units overvoltage protection provided on single output units and only the main output of multiple output units. map130 - 1012 map130 - 1024 all other models 17.0 32.0 5.5 22.0 37.0 6.8 vdc overcurrent protection all models have inherent short circuit protection. units will automatically restart at the removal of the fault. remote sense total voltage compensation for main output cable losses. 250 mv power fail warning 7 logic lo (denotes power fail detected). 0.7 v logic hi with internal pull - up to output. 10 k power fail trip point, maximum load, decreasing line. 86 94 vac time before regulation dropout, at full load, due to loss of input power. 5 ms overtemperature warning 8 warning prior to system shutdown due to excessive internal temperatures. shifts power fail signal to a logic lo state. 20 ms 7 power fail not available on map130 - 1012 and map130 - 1024. 8 map130 - 1012 and map130 - 1024 have overtemperature protection, but do not have the warning feature.
4 map130 series tech.support@psbel.com parameter conditions / description min nom max units agency approvals approved to the latest edition of the following standards; ul/csa60950 - 1 2nd, iec60950 - 1 2nd and en60950 - 1 2nd. dielectric withstand voltage input to chassis input to output (tested by manufacturer only) 2121 4242 vdc electromagnetic interference fcc cfr title 47 part 15 sub - part b - conducted en55022 / cispr 22 conducted en55022 / cispr 22 radiated 9 b b b class esd susceptibility per en61000 - 4 - 2, level 4 8 kv radiated susceptibility per en61000 - 4 - 3, level 3 10 v/m eft/burst per en61000 - 4 - 4, level 3 10 2 kv input transient protection en61000 - 4 - 5 level 3 line to line line to ground 1 2 kv insulation resistance input to output 7 m leakage current per en60950, 264 vac 700 a 9 map130 - 1005 meets class a, radiated. 1 0 map130 - 1005, map130 - 4003, and map130 - 4010, meet level 2, 1kv. parameter conditions / description min nom max units altitude operating non - operating 10k 40k feet operating temperature 11 derate linearly above 50c by 2.5% p er c at 100% load: at 50% load: 0 0 50 70 c storage temperature - 40 85 c temperature coefficient 0c to 70c (after 15 minute warm - up) 0.02 0.05 %/c relative humidity non - condensing 5 95 %rh shock operating, peak acceleration 20 g pk vibration random vibration, 10hz to 2khz, 3 axis 6 g rms 11 external airflow of minimum 23 cfm used in ambient over 25c. parameter conditions / description min nom max units dimensions 215.9 x 114.3 x 50.8 8.50 x 4.50 x 2.00 mm in weight 1.13 2.5 k g lb cover (option) o rder the cover number 412 - 59586 - g separately. for convection cooled applications with covers, derate output power as follows: derate all multiple output models and map130 - 1005 to 120 watts. derate map130 - 1012 and map130 - 1024 to 140 watts. dimensions: 215.9 x 114.3 x 55.1 8.5 x 4.5 x 2.17 mm in
map130 series 5 asia - pacific +86 755 298 85888 europe, middle east +353 61 225 977 north america +1 408 785 5200 ? 2016 bel power solutions & protection bcd.00567 _a c connector conditions / description input & output connectors 6 - 32 screw wire clamps on 0.312" (7.9 mm) centers, 0.045" (1.1 mm) square pins on 0.156" (3.96 mm) centers, mates with molex series 2139, 6442 & 41695 matting connectors 0.035" (0.89 mm) square pins on 0.100" (2.54 mm) centers; mates with molex series 2 695 & 6471 chassis 0.090" (2.286 mm) aluminum alloy with clear finish figure 1. mechanical drawing nuclear and medical applications - products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. technical revisions - the appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. specifications are subject to change without notice.


▲Up To Search▲   

 
Price & Availability of MAP130-1024G

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X